Deficiences of practical eskom currently uses for setting out-of-step relays

dc.contributor.authorDe Villiers, Louw Nicolaas Francois
dc.date.accessioned2006-10-26T07:35:06Z
dc.date.available2006-10-26T07:35:06Z
dc.date.issued2006-10-26T07:35:06Z
dc.descriptionFaculty of Engineering and the Built Environment; School of Electrical and Information Engineering; MSC Dissertationen
dc.description.abstractIn the recent past the Eskom network operated out-of-step at three occasions. Eskom questions whether the out-of-step relays responded as they should have. This is based on the fact that not all the out-of-step relays operated during these events. This dissertation shows that shunts can make the impedance locus behave nonclassically to the extent that the present practices Eskom uses for out-of-step relaying become inappropriate for application at certain busbars of the network. This is illustrated by showing that when the characteristic of the relay at Hydra, situated on the Mpumalanga side of Hydra, is set using the classical approach, the mentioned relay will not detect swings that have their electrical centre south of Hydra. A modified two generator model is used to show the effect shunts have. The phrase “improved two generator model” refers to this model. The improved two generator model is derived to represent the section of the Eskom network that links Mpumalanga to the Western Cape.en
dc.format.extent38969 bytes
dc.format.extent65134 bytes
dc.format.extent91744 bytes
dc.format.extent54698 bytes
dc.format.extent108705 bytes
dc.format.extent45507 bytes
dc.format.extent99044 bytes
dc.format.extent58534 bytes
dc.format.extent1460470 bytes
dc.format.extent760280 bytes
dc.format.extent548606 bytes
dc.format.extent3406195 bytes
dc.format.extent162033 bytes
dc.format.extent98109 bytes
dc.format.extent150156 bytes
dc.format.extent156270 bytes
dc.format.extent284874 bytes
dc.format.extent281550 bytes
dc.format.extent156663 bytes
dc.format.extent88903 bytes
dc.format.extent161631 bytes
dc.format.extent216774 bytes
dc.format.extent141770 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10539/1450
dc.language.isoenen
dc.subjectEskom networken
dc.subjectEskomen
dc.subjectrelaysen
dc.subjectout-of-step relaysen
dc.subjectbusbarsen
dc.subjectHydraen
dc.titleDeficiences of practical eskom currently uses for setting out-of-step relaysen
dc.typeThesisen

Files

Original bundle

Now showing 1 - 5 of 23
No Thumbnail Available
Name:
App-A.pdf
Size:
138.45 KB
Format:
Adobe Portable Document Format
Description:
Appendix A
No Thumbnail Available
Name:
APP-B.pdf
Size:
211.69 KB
Format:
Adobe Portable Document Format
Description:
Appendix B
No Thumbnail Available
Name:
APP-C.pdf
Size:
157.84 KB
Format:
Adobe Portable Document Format
Description:
Appendix C
No Thumbnail Available
Name:
APP-D.pdf
Size:
86.82 KB
Format:
Adobe Portable Document Format
Description:
Appendix D
No Thumbnail Available
Name:
APP-E.pdf
Size:
152.99 KB
Format:
Adobe Portable Document Format
Description:
Appendix E

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
101 B
Format:
Item-specific license agreed upon to submission
Description:

Collections