Modelling the cooling of concrete by piped water

dc.contributor.authorMyers, T.G.
dc.contributor.authorFowkes, N.D.
dc.contributor.authorBallim, Y.
dc.date.accessioned2012-01-30T08:45:46Z
dc.date.available2012-01-30T08:45:46Z
dc.date.issued2009-03-25
dc.departmentCivil Engineering
dc.descriptionLarge concrete structures are usually made sequentially in a series of blocks. After each block is poured it must be left to cool and shrink for a period depending on its size, but typically for around 1 week, before the next block is poured. The reason for the delay is that the mixture of cement and water, which constitute the binding agent of the concrete, results in a series of hydration reactions that generate heat.en_US
dc.description.abstractThe chemical reaction can lead to temperature rises in excess of 50 K and it can take a number of years before the concrete cools to the ambient temperature. Prior to construction of the Hoover dam engineers at the U.S. Bureau of Reclamation estimated that if the dam were built in a single continuous pour the concrete would require 125 years to cool to the ambient temperature and that the resulting stresses would have caused the dam to crack and fail (U.S. Bureau of Reclamation 2005).en_US
dc.identifier.urihttp://hdl.handle.net/10539/11189
dc.language.isoenen_US
dc.subjectDryingen_US
dc.subjectTemperatureen_US
dc.subjectModellingen_US
dc.titleModelling the cooling of concrete by piped wateren_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ASCE Meyers et al preprint.pdf
Size:
275.76 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: