Fabrication of a polymeric microneedle array for the decalcification of blood vessels

dc.contributor.authorMoodley, Kimaya
dc.contributor.co-supervisorMarimuthu, Thashree
dc.contributor.supervisorChoonara, Yahya E.
dc.date.accessioned2025-09-11T06:43:44Z
dc.date.issued2024
dc.descriptionA research report submitted in fulfillment of the requirements for the Master of Pharmacy, In the Faculty of Health Sciences, School of Therapeutic Sciences, University of the Witwatersrand, Johannesburg, 2024
dc.description.abstractBlood tissue calcification involves the deposition of calcium and phosphate minerals, predominantly within blood vessel walls, impacting cardiovascular health. Blood vessel calcification remains a significant concern in cardiovascular health, contributing to various complications such as medial arterial calcification (MAC) and intimal atherosclerotic calcification. While traditional treatment options have limitations, emerging research suggests that ethylenediaminetetraacetic acid (EDTA) could serve as a promising chelating agent to reverse calcification. When delivered in close proximity to the calcification site, EDTA has shown potential for mitigating calcification progression and restoring vascular function. This study aimed to develop a dissolvable polymeric microneedle (MN) array to be loaded with EDTA to treat vascular calcification in a site specific manner. Two MN formulations were prepared, the first from a combination of chitosan, polyvinyl alcohol and hydroxypropyl cellulose and the second from a cross-linked sodium alginate solution using a mould-based method. EDTA was successfully loaded into both MN formulations for further evaluation. Chitosan MN arrays were loaded with 340 μg of EDTA while alginate arrays were loaded with 965.8 μg of EDTA. The arrays were analysed by, differential scanning calorimetry (DSC), powder x-ray diffraction (PXRD) spectroscopy and Fourier transform infrared (FTIR) spectroscopy. The morphological features and mechanical strength, were investigated by scanning electron microscopy and texture analysis respectively. The fabricated arrays were of 8 mm x 8mm patch size containing 10 x 10 needles. Each needle has a length of 300 μm, needle base of 100μm and needle pitch of 500μm. It was shown that MN arrays were mechanically sufficiently strong to penetrate the vascular tissue. The typical failure force ranged from 0.338 to 0.345 Newton per needle for chitosan and alginate MN arrays respectively. Chitosan MN arrays achieved a 315 μg release within 24 hours while alginate arrays released 789 μg in the same period. Drug permeation studies were carried out on porcine venous tissue and showed in enhanced permeation ability of the alginate arrays after 6 hours. The MN arrays also both showed good hemocompatibility via hemolysis testing, with no significant increase in hemolysis and calcium chelating ability based on the quantity of EDTA permeating the tissue layer. Overall, this study resulted in the successful preparation of two dissolvable, EDTA loaded MN arrays from natural polymers using a simple, mould-based method. These MNs were found to penetrate the vascular tissue with minimal application forces and release bioactive over a 24 hour period. These polymeric MNs could prove useful for the delivery of many other drugs to the vascular system which would benefit therapeutic outcomes of patients greatly.
dc.description.sponsorshipNational Research Foundation
dc.description.submitterMM2025
dc.facultyFaculty of Health Sciences
dc.identifier0000-0003-0997-9502
dc.identifier.citationMoodley, Kimaya . (2024). Fabrication of a polymeric microneedle array for the decalcification of blood vessels [Master`s dissertation, University of the Witwatersrand, Johannesburg]. WIReDSpace. https://hdl.handle.net/10539/46361
dc.identifier.urihttps://hdl.handle.net/10539/46361
dc.language.isoen
dc.publisherUniversity of the Witwatersrand, Johannesburg
dc.rights© 2024 University of the Witwatersrand, Johannesburg. All rights reserved. The copyright in this work vests in the University of the Witwatersrand, Johannesburg. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of University of the Witwatersrand, Johannesburg.
dc.rights.holderUniversity of the Witwatersrand, Johannesburg
dc.schoolSchool of Therapeutic Sciences
dc.subjectUCTD
dc.subjectVascular
dc.subjectmicroneedle
dc.subjectpolymer
dc.subjectdrug delivery
dc.subject.primarysdgSDG-3: Good health and well-being
dc.titleFabrication of a polymeric microneedle array for the decalcification of blood vessels
dc.typeDissertation

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Moodley_Fabrication _2024.pdf
Size:
2.37 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.43 KB
Format:
Item-specific license agreed upon to submission
Description: