Evaluation of pipe stub flange behaviour during hydrostatic pressure testing
dc.contributor.author | Asumani, Oscar | |
dc.date.accessioned | 2008-05-16T07:19:21Z | |
dc.date.available | 2008-05-16T07:19:21Z | |
dc.date.issued | 2008-05-16T07:19:21Z | |
dc.description.abstract | ABSTRACT An evaluation of glass reinforced plastic pipe stub-flange behaviour during hydrostatic pressure testing is presented. Similar flanges made according to different manufacturing methods were analysed. Linear static analysis using MSC Patran / Nastran was performed to predict the critically loaded regions subjected to high stress concentrations. These regions were used for experimental strain gauge locations. Hydrostatic testing designed according to BS 5480 and ASTM F 37 was performed on assembled flange joints to initiate both leakage and ultimate material failure. Experimental strain results were compared to finite element numerical results at the selected locations. Fibre dominated failure characterised by cracks extending through the stub and matrix dominated failure characterised by interlaminar debonding were noticed. The need for further work analyzing GRP flanges subject to mechanical load and taking into account induced residual thermal stress effects is suggested. | en |
dc.format.extent | 9998 bytes | |
dc.format.extent | 16045 bytes | |
dc.format.extent | 19645 bytes | |
dc.format.extent | 13823 bytes | |
dc.format.extent | 18800 bytes | |
dc.format.extent | 21440 bytes | |
dc.format.extent | 19855 bytes | |
dc.format.extent | 989309 bytes | |
dc.format.extent | 78778 bytes | |
dc.format.extent | 929660 bytes | |
dc.format.extent | 107337 bytes | |
dc.format.extent | 553982 bytes | |
dc.format.extent | 255024 bytes | |
dc.format.extent | 26509 bytes | |
dc.format.extent | 1039115 bytes | |
dc.format.extent | 10910 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.identifier.uri | http://hdl.handle.net/10539/4833 | |
dc.language.iso | en | en |
dc.subject | pipe stub flange | en |
dc.subject | glass reinforced plastic | en |
dc.subject | finite element analysis | en |
dc.subject | pressure testing | en |
dc.title | Evaluation of pipe stub flange behaviour during hydrostatic pressure testing | en |
dc.type | Thesis | en |
Files
Original bundle
1 - 5 of 16
No Thumbnail Available
- Name:
- AsumaniO_Abstract.pdf
- Size:
- 10.65 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- AsumaniO_Appendices.pdf
- Size:
- 1014.76 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- AsumaniO_Chapter 1.pdf
- Size:
- 25.89 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- AsumaniO_Chapter 2.pdf
- Size:
- 249.05 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- AsumaniO_Chapter 3.pdf
- Size:
- 541 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 96 B
- Format:
- Item-specific license agreed upon to submission
- Description: