Spreadability of two glass ionomer cements used in Atraumatic Restorative Treatment (ART)

dc.contributor.authorSindhu, R.
dc.contributor.authorGrossman, E. S.
dc.date.accessioned2016-04-29T10:08:54Z
dc.date.available2016-04-29T10:08:54Z
dc.date.issued2004
dc.descriptionKIMen_ZA
dc.description.abstract'Press finger' in atraumatic restorative treatment (ART) is used to spread a glass ionomer cement (GIC) to seal the restoration margin and adjacent pits and fissures. This study compared the spreadability of Fuji IX and Ketac-Molar to establish which was best suited for this purpose. Twenty equally spaced cavities (35 mm apart) were machine-cut in each of two Perspex slabs 200 x 100 x 20 mm. Each cavity was 3 mm deep with a 4 mm diameter. Two V-shaped grooves 1 mm deep were cut to traverse the cavities: one 0.5 mm wide, the other 0.25 mm wide. Equal amounts (0.25 ml) of GIC were dispensed, 20 cavities for Fuji IX and 20 for Ketac-Molar and condensed under light finger pressure using a 20 mm diameter cork thinly coated with petroleum jelly. This allowed the GIC to be condensed into the cavity and spread into the differently sized grooves. The samples were stored in deionised water for 24 hours whereafter the length to which the GIC had spread along each groove from the cavity edge was measured to the closest 0.01 mm. The data were analysed using ANOVA and the unpaired Student's t-test (P < 0.05). There was a statistically significant difference between the length of spread of the two GICs (t = 2.534; P = 0.013) which was confined to the 0.25 mm width groove (t = 2.83; P = 0.007) with Fuji IX spreading much further along the groove (10.25 +/- 1.17 mm) than Ketac-Molar (7.66 +/- 4.21 mm). Fuji IX appears to be the better sealant material when selecting for spreadability in ART.en_ZA
dc.identifier.citationSindhu,R., Grossman,E.S. 2004. Spreadability of two glass ionomer cements used in Atraumatic Restorative Treatment (ART).Journal of the South African dental association;59(1):24-26en_ZA
dc.identifier.urihttp://hdl.handle.net/10539/20275
dc.language.isoenen_ZA
dc.subjectDental Restoration, Permanenten_ZA
dc.subjectViscosityen_ZA
dc.subjectGlass Ionomer Cementsen_ZA
dc.subjectDental Modelsen_ZA
dc.titleSpreadability of two glass ionomer cements used in Atraumatic Restorative Treatment (ART)en_ZA
dc.typeArticleen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Spreadability of two glass ionomer cements used in ART.pdf
Size:
241.23 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: