On-line process monitoring in electrolytic manufacturing of chromic acid
No Thumbnail Available
Date
2009-03-12T11:27:44Z
Authors
Van Rooyen, Daniel J.R.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
dichromate content in concentrated liquors from the electrolytic production of
chromic acid were investigated.
Experimental results showed that Artificial Neural Network technology applied to
highly diluted hexavalent chromium solutions, which are known to have been
prepared from chromic acid and sodium dichromate, do not yield useable results
for quantification purposes.
Combining ion selective electrode measurements and ultra-violet – visible
spectrophotometric techniques to highly diluted hexavalent chromium solutions,
prepared from chromic acid and sodium dichromate, yields errors of about 2.3 %
for hexavalent chromium and about 2.8 % for sodium determinations versus a
standard titrimetric method.
Tests to prove the suitability of the standard titrimetric acid –base titration
technique confirmed an accuracy of 0.6 % for a known chromic acid content and
0.7 % for titrations based on a known sodium dichromate content for liquors
highly concentrated in hexavalent chromium.
A simple on-line analytical instrument was developed based on the titrimetric acid
–base titration technique. The on-line instrument evidenced average errors of
about 1.9 % for the chromic acid content and about 2.6 % for the sodium
dichromate content.