Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm
dc.contributor.author | Goldstein, L.N. | |
dc.contributor.author | Wells, M. | |
dc.contributor.author | Sliwa, K. | |
dc.date.accessioned | 2016-04-29T12:07:49Z | |
dc.date.available | 2016-04-29T12:07:49Z | |
dc.date.issued | 2014-12 | |
dc.department | Molecular Medicine and Haematology | |
dc.description.abstract | Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). Methods. This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer’s guidelines. The arm and ankle BP measurements were compared. Results. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (–13 mmHg, 95% confidence interval (CI) –28 - 1 mmHg and –5 mmHg, 95% CI –13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI –7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Conclusion. Ankle BP cannot be used as a substitute for arm BP in the ED. | |
dc.faculty | Faculty of Health Sciences | |
dc.identifier.citation | Goldstein, L.N., Wells, M., Sliwa, K. 2014. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm. SAMJ;104(12):869-873 | en_ZA |
dc.identifier.doi | 10.7196/SAMJ.8102 | |
dc.identifier.issn | 0256-9574 (print) | |
dc.identifier.issn | 2078-5135 (online) | |
dc.identifier.uri | http://hdl.handle.net/10539/20272 | |
dc.journal.title | South African Medical Journal | |
dc.language.iso | en | en_ZA |
dc.rights | © The Authors 2014. This article is licensed under a Creative Commons Attribution - Noncommercial Works License. | |
dc.school | School of Pathology | |
dc.subject | Blood Pressure | en_ZA |
dc.subject | Blood Pressure Determination | en_ZA |
dc.subject | Ankle blood pressure measurements | |
dc.subject | Arm blood pressure measurements | |
dc.title | Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm | en_ZA |
dc.type | Article | en_ZA |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm..pdf
- Size:
- 593.79 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: