Microbial contamination and labelling of self-prepared, multi-dose phenylephrine solutions used at a teaching hospital

dc.contributor.authorVan den Heever, Zacharias Andreas Neethling
dc.date.accessioned2015-04-08T09:59:12Z
dc.date.available2015-04-08T09:59:12Z
dc.date.issued2013
dc.descriptionA research report submitted to the Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, in partial fulfilment of the requirements for the degree of Master of Medicine in the branch of Anaesthesiology Johannesburg, 2013
dc.description.abstractBackground: Microbial contamination of multi-dose vials is one of the mechanisms by which transmission of pathogens to patients can occur in anaesthesia. Common practice at Chris Hani Baragwanath Academic Hospital (CHBAH) is to use boluses of a self-prepared, multi-dose phenylephrine solution (referred to as the solutions) to treat hypotension, due to the vasodilatory effects of a spinal anaesthetic, in stable patients undergoing a caesarean section. Aims: The aims of this study were to determine if there was microbial contamination of the solutions used at CHBAH and to evaluate if appropriate labelling and aspiration practices were adhered to with regard to the solutions A sample was collected and the labelling data was documented from the solutions found in the obsteric theatres at CHBAH over a period of three months. The samples were sent to a laboratory for microbial investigation. Microbial contamination was identified in seven of 110 (6.36%) samples collected from the solutions. The name of the solution was indicated on all 110 (100%) containers and the concentration of the solution was indicated on 106 (96.36%) containers. The date the solution was prepared was indicated on 82 (74.55%) containers and the time the solution was prepared was indicated on 63 (57.27%) containers. Only nine (8.18%) of the healthcare workers that prepared the solutions confirmed it by placing a signature on the container. Labelling data was written directly on all 110 (100%) containers and a spike device was used in 71 (64.54%) containers. This study demonstrated microbial contamination of the solutions and that safe injection practices were not adhered to when intravenous medications were prepared and administered. This is important at CHBAH since a large proportion of South African patients are immunocompromised and susceptible to opportunistic infections. Inappropriate labelling of medications is a cause of medication administration errors and this may have serious legal implications for the anaesthetist.en_ZA
dc.identifier.urihttp://hdl.handle.net/10539/17403
dc.language.isoenen_ZA
dc.subject.meshPhenylephrine
dc.subject.meshDrug Labeling
dc.subject.meshDrug Contamination
dc.titleMicrobial contamination and labelling of self-prepared, multi-dose phenylephrine solutions used at a teaching hospitalen_ZA
dc.typeThesisen_ZA
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Abstract Microbial contamination and labelling of self-prepared, multi-dose phenylephrine solutions used at a teaching ho~1.pdf
Size:
56.74 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
MMed Microbial contamination and labelling of self-prepared, multi-dose phenylephrine solutions used at a teaching hospit~1.pdf
Size:
4 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections