Comparison of lodox whole body slit beam technology with traditional radiography for evaluation of radioprotective lead aprons

dc.contributor.authorMahango, Kate Mahlako
dc.date.accessioned2021-10-13T13:18:34Z
dc.date.available2021-10-13T13:18:34Z
dc.date.issued2020
dc.descriptionA research report submitted in partial fulfilment of the requirements for the degree of Master of Medicine in Radiology to the Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, 2020en_ZA
dc.description.abstractINTRODUCTION: The Lodox Statscan is a digital low radiation dose X-ray unit. Its ability to also scan a full patient length in a few seconds with equivocal image quality to conventional radiography, has led to its use in multiple trauma units. We intended to extend the application of the Lodox Statscan in the Quality Assurance program of Charlotte Maxeke Johannesburg Academic Hospital (CMJAH), by utilizing the device to evaluate the integrity of lead aprons. AIM: This study aimed to compare Lodox Statscan with Fluoroscopic evaluation of radioprotective lead aprons with regard to the integrity of the lead shielding. METHOD: 35 lead aprons from the Radiology department at Charlotte Maxeke Johannesburg Academic Hospital were collected and imaged using Fluoroscopy and Lodox Statscan. The digitally recorded images of the lead aprons were assessed to determine the presence, number and size of lead apron fractures. The Lodox Statscan findings and conventional radiography findings, including time taken to assess each apron, were compared.RESULTS: Lodox Statscan, was faster in acquiring images, with an average procedure time of 1.43 minutes, compared to an average time of 5.72 minutes with Fluoroscopy. In terms of identifying fractures, the two methods displayed no statistical difference (pvalue: 0.33). No statistical difference was found in the fractures scores (total number of fractures detected) between the two imaging technologies (p-value: 0.79). CONCLUSIONS: The findings of this study have shown that compared to the gold standard fluoroscopic examination, Lodox examination of lead aprons is a feasible option in determining the integrity of lead aprons.en_ZA
dc.description.librarianTL (2021)en_ZA
dc.facultyFaculty of Health Sciencesen_ZA
dc.identifier.urihttps://hdl.handle.net/10539/31710
dc.language.isoenen_ZA
dc.schoolSchool of Medicineen_ZA
dc.titleComparison of lodox whole body slit beam technology with traditional radiography for evaluation of radioprotective lead apronsen_ZA
dc.typeThesisen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
FINAL Manuscript 2 (3) (00000002) (1).pdf
Size:
607.62 KB
Format:
Adobe Portable Document Format
Description:
Main Work
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections