    Modelling the cooling of concreate by piped water
    (2009-03-25) Myers, T.G.; Fowkes, N.D.; Ballim, Y.
    Piped water is used to remove hydration heat from concrete blocks during construction. In this paper we develop an approximate model for this process. The problem reduces to solving a one-dimensional heat equation in the concrete, coupled with a first order differential equation for the water temperature. Numerical results are presented and the effect of varying model parameters shown. An analytical solution is also provided for a steady-state constant heat generation model. This helps highlight the dependence on certain parameters and can therefore provide an aid in the design of cooling systems.