School of Pathology (Journal Articles)

Permanent URI for this collectionhttps://hdl.handle.net/10539/37877

Browse

Search Results

Now showing 1 - 3 of 3
  • Thumbnail Image
    Item
    Evaluation of automated malaria diagnosis using the Sysmex XN-30 analyser in a clinical setting
    (BioMed Central, 2019-01) Pillay, Evashin; Bezuidenhout, Belinda C.; Coetzer, Thérèsa L.; Khodaiji, Shanaz; Litshie, Monwabisi
    Background: Early and accurate diagnosis of malaria is a critical aspect of eforts to control the disease, and several diagnostic tools are available. Microscopic assessment of a peripheral blood smear enables direct visualization of parasites in infected red blood cells and is the clinical diagnostic gold standard. However, it is subjective and requires a high level of skill. Numerous indirect detection methods are in use, but are not ideal since surrogate markers of infection are measured. This study describes the frst clinical performance evaluation of the automated Sysmex XN-30 analyser, which utilizes fuorescence fow cytometry to directly detect and quantitate parasite-infected red blood cells. Results: Residual EDTA blood samples from suspected malaria cases referred for routine diagnosis were analysed on the XN-30. Parasitaemia was reported as a percentage, as well as absolute numbers of infected red blood cells, and scattergrams provided a visual image of the parasitized red blood cell clusters. The results reported by the XN-30 correlated with microscopy and the analyser demonstrated 100% sensitivity and specifcity. Measurements were reproducible and storage of samples at room temperature did not afect the parameters. Several Plasmodium species were detected, including Plasmodium falciparum, Plasmodium vivax and Plasmodium ovale. The XN-30 also identifed the transmissible gametocytes as a separate cluster on the scattergrams. Abnormal red blood cell indices (low haemoglobin and raised reticulocyte counts), haemoglobinopathies and thrombocytopenia did not interfere with the detection of parasites. The XN-30 also generated a concurrent full blood count for each sample. Conclusions: The novel technology of the Sysmex XN-30 provides a robust, rapid, automated and accurate platform for diagnosing malaria in a clinical setting. The objective enumeration of red blood cells infected with Plasmodium species makes it suitable for global use and allows monitoring of the parasite load once therapy has been initiated, thereby providing an early marker of drug resistance. The automated generation of a full blood count for each sample provides an opportunity for detecting unsuspected cases. Asymptomatic carriers can also be identifed, which will be useful in blood transfusion centres, and will enable treatment of these individuals to prevent the spread of the disease.
  • Thumbnail Image
    Item
    Molecular and physiological analysis of Anopheles funestus swarms in Nchelenge, Zambia
    (BMC, 2018-01) Zawada, Jacek W.; Dahan‑Moss, Yael L.; Muleba, Mbanga; Dabire, Roch K.; Maïga, Hamid; Venter, Nelius; Davies, Craig; Hunt, Richard H.; Coetzee, Maureen; Koekemoer, Lizette L.
    Background: Anopheles funestus has been recognized as a major malaria vector in Africa for over 100 years, but knowledge on many aspects of the biology of this species is still lacking. Anopheles funestus, as with most other anophelines, mate through swarming. A key event that is crucial for the An. funestus male to mate is genitalia rotation. This involves the 135° to 180° rotation of claspers, which are tipped with claws. This physical change then enables the male to grasp the female during copulation. The aim of this investigation was to molecularly characterize wild An. funestus swarms from Zambia and examine the degree of genitalia rotation within the swarm. Methods: Anopheles funestus swarms were collected from Nchelenge, northern Zambia, during dusk periods in May 2016. All the adults from the swarm were analysed morphologically and identified to species level using a multiplex PCR assay. Anopheles funestus s.s. specimens were molecularly characterized by restriction fragment length polymorphism type and Clade type assays. The different stages of genitalia rotation were examined in the adult males. Results: A total of six swarms were observed during the study period and between 6 and 26 mosquitoes were caught from each swarm. Species analysis revealed that 90% of the males from the swarms were An. funestus s.s. MWtype, with 84% belonging to clade I compared to 14% clade II and 2% failed to amplify. Very few specimens (3.4%) were identified as Anopheles gambiae s.s. Eighty percent of the males from the swarm had complete genitalia rotation. Conclusions: This is the first time that An. funestus swarms have been molecularly identified to species level. Anopheles funestus swarms appear to be species-specific with no evidence of clade-type differentiation within these swarms. The An. funestus swarms consist mainly of males with fully rotated genitalia, which strongly suggests that swarming behaviour is triggered primarily when males have matured.
  • Thumbnail Image
    Item
    The importance of morphological identification of African anopheline mosquitoes (Diptera: Culicidae) for malaria control programmes
    (BioMed Central (BMC), 2018-01) Erlank, Erica; Koekemoer, Lizette L.; Coetzee, Maureen
    Background: The correct identification of disease vectors is the first step towards implementing an effective control programme. Traditionally, for malaria control, this was based on the morphological differences observed in the adults and larvae between different mosquito species. However, the discovery of species complexes meant that genetic tools were needed to separate the sibling species and today there are standard molecular techniques that are used to identify the two major malaria vector groups of mosquitoes. On the assumption that species-diagnostic DNA polymerase chain reaction (PCR) assays are highly species-specific, experiments were conducted to investigate what would happen if non-vector species were randomly included in the molecular assays. Methods: Morphological keys for the Afrotropical Anophelinae were used to provide the a priori identifications. All mosquito specimens were then subjected to the standard PCR assays for members of the Anopheles gambiae complex and Anopheles funestus group. Results: One hundred and fifty mosquitoes belonging to 11 morphological species were processed. Three species (Anopheles pretoriensis, Anopheles rufipes and Anopheles rhodesiensis) amplified members of the An. funestus group and four species (An. pretoriensis, An. rufipes, Anopheles listeri and Anopheles squamosus) amplified members of the An. gambiae complex. Conclusions: Morphological identification of mosquitoes prior to PCR assays not only saves time and money in the laboratory, but also ensures that data received by malaria vector control programmes are useful for targeting the major vectors.