ETD Collection

Permanent URI for this collectionhttps://wiredspace.wits.ac.za/handle/10539/104


Please note: Digitised content is made available at the best possible quality range, taking into consideration file size and the condition of the original item. These restrictions may sometimes affect the quality of the final published item. For queries regarding content of ETD collection please contact IR specialists by email : IR specialists or Tel : 011 717 4652 / 1954

Follow the link below for important information about Electronic Theses and Dissertations (ETD)

Library Guide about ETD

Browse

Search Results

Now showing 1 - 1 of 1
  • Item
    Problems experienced with low-profile dynamic splints
    (1994) Van Velze, Cornelia Anna
    Many patients have been supplied with dorsal dynamic finger extension splints for improvement of the range of motion of stiff finger joints, The design of the splint has been developed and improved over time, but the amount of force which was applied to a finger was determined intuitively. This research was undertaken to quantify the force exerted on a finger and to design a splint which would ensure that the amount of force exerted on a finger was constant and reliable. Since six studies were undertaken as part of the research, different protocols were developed for each. The findings of the studies can be summarised as follows: similar tensions in a variety of rubber bands can not oonsistently be identified; rubber bands which are more or less equal in length, thickness and width do not undergo the same amount of elongation when identical weights are attached to them; friction between the outrigger and the traction unit plays a major role in determining how much force is exerted on a finger; a layer of Teflon paint over the outrigger coupled with a nylon fishing line traction unit causes the least amount of friction; stainless steel tension springs provide a more reliable and consistent force than rubber bands. Finally a splint was designed, taking into account the results of the six studies. The splint consists of a thermoplastic base with Velcro attachment straps, a pre-notched copper coated welding rod dipped in Teflon paint at least 14 days before use, a traction unit made from a stainless steel tension spring with a tension of 3g/rnm, a piece of nylon fishing line and a finger sling. Although the splint was designed to ensure that the force exerted on a finger is consistent and quantifiable, it should still be tested clinically to ascertain whether the design is really practical.