Accuracy of polyether vs plaster impressions for long-span implant supported prosthesis

dc.contributor.authorVon Berg, George Botha
dc.date.accessioned2008-02-29T11:05:03Z
dc.date.available2008-02-29T11:05:03Z
dc.date.issued2008-02-29T11:05:03Z
dc.description.abstractABSTRACT Two different implant impression materials viz. a polyether (Impregum ®) and a plaster (Plastogum ®) impression material were used and compared with respect to the accuracy with which abutment positions were reproduced from a stainless steel master model containing five implant analogues. Ten polyether impressions and ten plaster impressions were taken and cast in stone. The positions of the precision impression copings on the twenty impressions were measured using a Reflex Microscope. The positions of the implant analogues on the twenty casts were also measured and compared to the positions on the stainless steel master model. Statistical analysis indicated significant differences between the polyether impression and the plaster impression for full arch implant supported prostheses. The use of plaster resulted in smaller interabutment error but with less predictable variance in dimensions.en
dc.format.extent1093237 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10539/4503
dc.language.isoenen
dc.subjectAccuracyen
dc.subjectLong-spanen
dc.titleAccuracy of polyether vs plaster impressions for long-span implant supported prosthesisen
dc.typeThesisen
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Binder1.pdf
Size:
1.04 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
96 B
Format:
Item-specific license agreed upon to submission
Description:
Collections